cam-bien-khoang-canh-dme5000-112.png

Cảm biến khoảng cánh DME5000-112

Long range distance sensors
DME5000

Dich vụ sửa chữa, bảo dưỡng, cải tiến các hệ thống dây chuyền tự động công nghiệp 

  • Performance
    Measuring range 0.15 m ... 70 m, on reflective tape "Diamond Grade" 1)
    Target Reflector
    Resolution 0.05 mm ... 5 mm
    Repeatability 0.5 mm 1) 2)
    Accuracy ± 2 mm
    Response time 6 ms
    Output time 2 ms
    Light source Laser, red 3)
    Laser class 2, complies with 21 CFR 1040.10 and 1040.11 except for the tolerance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014)
    Typ. light spot size (distance)

    130 mm (at 70 m)

    270 mm (at 150 m)

    360 mm (at 220 m)

    Max. movement speed 10 m/s
    • 1) On reflective tape "Diamond Grade".
    • 2) Statistical error 1 σ, environmental conditions constant, min. warm-up time 10 min.
    • 3) Average service life of 50,000 h at TA = +25 °C.
  • Interfaces
    PROFIBUS DP
    Switching output Push-pull: PNP/NPN (100 mA) 1)
    Multifunctional input (MF) 1 x MF 2) 3)
    • 1) HIGH = > VS - 3 V / LOW = < 2 V.
    • 2) HIGH = > 12 V / LOW = < 3 V.
    • 3) Not reverse-polarity protected.

 

  • Mechanics/electronics
    Supply voltage Vs DC 18 V ... 30 V, limit values
    Ripple < 5 Vpp 1)
    Initialization time 1.5 s 2)
    Connection type Male connector, 2 x M12, 5-pin, B-coded, 1 x M16, 8-pin, B-coded
    Indication Display
    Weight Approx. 1,650 g
    Output current IA ≤ 100 mA 3)
    Current consumption At 24 V DC < 250 mA
    Enclosure rating IP65
    Protection class II 4)
    • 1) May not fall short of or exceed VS tolerances.
    • 2) After loss of reflector < 1 s at max. speed Vmax < 1 m/s.
    • 3) Max. 100 nF/20 mH.
    • 4) Reference voltage DC 32 V.
Ambient data
Electromagnetic compatibility (EMC) EN 61000-6-2, EN 55011
Ambient temperature operation

–10 °C ... +55 °C

–10 °C ... +75 °C, operation with cooling case

Ambient storage temperature –25 °C ... +75 °C
Effect of air pressure 0.3 ppm/hPa
Effect of air temperature 1 ppm/K
Temperature drift Typ. 0.1 mm/K
Typ. Ambient light immunity ≤ 40,000 lx
Mechanical load

Shock: (EN 600 68-2-27 / –2-29)

Sine: (EN 600 68-2-6)

Noise: (EN 600 68-2-64)

 

Classifications
ECl@ss 5.0 27270801
ECl@ss 5.1.4 27270801
ECl@ss 6.0 27270801
ECl@ss 6.2 27270801
ECl@ss 7.0 27270801
ECl@ss 8.0 27270801
ECl@ss 8.1 27270801
ECl@ss 9.0 27270801
ETIM 5.0 EC001825
ETIM 6.0 EC001825
UNSPSC 16.0901 41111613