GTS40/48D-0 Gefran Việt Nam

GTS 15/25/40/50/60/75/90/120A POWER SOLID STATE RELAYS WITH LOGIC CONTROL Vdc / Vac

 

GENERAL Turning an electric load on or off requires the use of a suitable interrupt and protection device that is safe and immune to disturbances. In addition, for optimum process control in many industrial applications, it is indispensable to drive the load with very short switching times: the best solution is the use of solid state relays. Gefran proposes the GTS range of power solid state relays with voltage zero crossing, currents from 10A to 120A, and rated voltages of 230Vac, 480Vac and 600Vac. All models are designed to guarantee operation at rated currents, with continuous driving of power at 40°C ambient temperature. For less critical operating conditions, you can use the products beyond rated currents (using the dissipation curves as reference). Various accessories are available, such as the attachment for panel fastening, fuses and fuse holders. ALARM OPTION: for models with AC control (Input type = “A”) OPERATING DESCRIPTION The alarm output option activates closing of an isolated contact when it detects the following fault conditions: • Control signal active but no current on load (zero current, interrupted load) • Control signal active but no power line voltage (no line) • Control signal active but SCR / heatsink is in overtemperature (GTS thermal protection) NOTE: in the absence of the control, the alarm output is always open (the alarm memory latch function is not possible, as with GTS with Type “D” input). Option function description: for models with DC control (Input type = “D”) The Alarm Output Function activates the output switch (or PNP digital output) when detects the following situations: • The control signal is ON, but there is not current in the Load (No Current, No Load condition) • The control signal is ON, but there is not GTS power Line voltage supply (No Line condition) • The control signal is ON, but the SCR / Heat sink is in overtemperature (GTS thermal protection condition) The alarm output is latched: its status it is maintained if the Control signal is switched off, the alarm output resets when the load current is restored or when the GTS 24V_supply is switched off and on (V_supply reset). The alarm output option is available as Insulated Solid State Switch (or as Digital Output PNP), with Normally open switch (or PNP normally non active) or normally closed switch (or PNP normally active) status.

TECHNICAL DATA General features Category of use: AC1 Rated working voltage - 230Vac (max. range 24...280Vac) - 480Vac (max. range 24...530Vac) - 600Vac (max range 24 ... 660Vac) Rated frequency: 50/60Hz Non-repetitive voltage: • 500Vp for model with rated voltage 230Vac • 1200Vp for model with rated voltage 480Vac • 1400Vp for model with rated voltage 600Va Switching voltage for zero: < 20V Activation time: = 1/2 cycle Deactivation time: = 1/2 cycle Potential drop at rated current: = < 1.4Vrms Power factor = 1 Control inputs - DC INPUT (Type “D”): Max. input: < 10mA @32V Max. reverse voltage: 36Vdc Control voltage: 6...32Vdc Activation voltage: > 5.1Vdc Deactivation voltage:< 3Vdc - AC INPUT (Type “A”): Control voltage: 20...260 (250)* VAC/VDC * CSA certification INSTALL FUSE (3A MAX) ON THE CONTROL INPUT CIRCUIT Activation voltage: > 15 Vac / Vdc Deactivation voltage: < 6 Vac / Vdc Current draw: <= 8 mAac/dc @ 260 Vac/Vdc Option: Load or line failure alarm option has a solid state output switch or PNP digital output (max ratings: 30V - 150mA conduction resistance 15ohm) Maximum delay in tripping of load interrupt alarm < 400ms Maximum length of wires between GS and load for correct operation of load diagnostics < 25m Outputs GTS 15 Rated current:15 A@40°C in continuous service Non-repetitive overcurrent t=20 ms: 400A I 2 t for blowout: ≤450A2 s dV/dt critical with output deactivated: 1000V/µs GTS 25 Rated current: 25 A@40°C in continuous service Non-repetitive overcurrent t=20 ms: 400A I 2 t for blowout: ≤645A2 s dV/dt critical with output deactivated: 1000V/µs GTS 40 Rated current: 40 A@40°C in continuous service Non-repetitive overcurrent t=20 ms: 600A I 2 t for blowout: ≤1010A2 s dV/dt critical with output deactivated: 1000 V/µs GTS 50 Rated current: 50 A@ 40°C in continuous service Non-repetitive overcurrent t=20 ms: 1150A I 2 t for blowout: ≤6600A2 s dV/dt critical with output deactivated: 1000V/µs GTS 60 Rated current: 60 A@ 40°C in continuous service Non-repetitive overcurrent t=20 ms: 1150A I 2 t for blowout: ≤6600A2 s dV/dt critical with output deactivated: 1000V/µs GTS 75 Rated current: 75 A@ 40°C in continuous service Non-repetitive overcurrent t=20 ms: 1300A I 2 t for blowout: ≤8000A2 s dV/dt critical with output deactivated: 1000V/µs GTS 90 Rated current: 90A@ 40°C in continuous service Non-repetitive overcurrent t=20 ms: 1500A I 2 t for blowout:≤11200A2 s dV/dt critical with output deactivated: 1000V/µs GTS 120 Rated current: 120A@ 40°C in continuous service (complete with fan standard) Non-repetitive overcurrent t=20 ms: 1500A I 2 t for blowout: ≤11200A2 s dV/dt critical with output deactivated: 1000V/µS TEMPLATE DIMENSIONS W L M5 L (mm) W (mm) GTS 15-25 112 0 GTS 40 112 25 GTS 50-60 112 44 GTS 75-90-120 112 1